top of page
AdobeStock_346073470.jpeg
GD600-Hero-1_edited.png

GD600 GAS
DILUTION SYSTEM

Automated Calibration Solution

The Scentroid GD600 Gas Dilution System simplifies the calibration of chemical analyzers. GD600 generates its own zero-air by scrubbing the ambient air using its 3-stage filter.

Most Utilized Industries

Screen Shot 2022-08-12 at 4.25_edited.png

Save on Gas

Reduce calibration gas consumption significantly with the GD600 dilution system. One gas bottle will last multiple calibrations

Screen Shot 2022-08-12 at 4.25_edited.png

Accuracy

Continuous dilution monitoring feedback for 100% reliability and accuracy. Medical grade mass flow controllers with 99.5% dilution accuracy

Screen Shot 2022-08-12 at 4.25_edited.png

Power Supply

The TR8 Odotracker provides automated continuous chemical, GPS position, temperature and humidity data logging

Screen Shot 2022-08-12 at 4.34_edited.png

System

Controlled through any device via Bluetooth connectivity. Displays environmental variables including temperature and humidity

Screen Shot 2022-08-12 at 4.25_edited.png

Zero Air Generator

Built-in zero air generator provides 7000 ml / min. System has a dilution range of 2 to 5,000

Screen Shot 2022-08-09 at 15.34_edited.png

No Power? No problem

The GD600 features a built-in battery for total portability. It comes packaged with a 120 – 240v charger

Related Products

Efficient and Cost Saving

The dilution system eliminates the need for sample bags. Normally, 3 gas canisters are required per sensor when calibrating. With this system, 1 bottle will last through multiple calibrations. Plus, there is no longer a need to remove equipment to send to a lab for re-calibration, removing expensive transportation costs and unnecessary labour. All processes are now infield.  

Overview of GD600 Gas Dilution System

The Scentroid GD600 Gas Dilution System provides an easy solution to simplify calibrating chemical analyzers. GD600 generates its own zero-air by scrubbing the ambient air using its 3-stage filter. Calibration gases are diluted using zero air or optionally N2 to provide a reference gas of any concentration. This allows the operator to easily conduct multi-point calibration. By controlling the mass flow of the reference gas, GD600 not only simplifies the calibration process but also reduces the consumption of reference gases. Through the user-friendly android app, the user can command the GD600 to perform single or multiple point calibrations simply by entering the desired gas concentrations and time between samplings for each point.

Ease of Use

Fully automated dilution. The user is only required to provide desired dilution and minimum output flow rate. Inlet for 0 – 10,000 ml/min dilutes N2/zero air from external sources. Scrubbers with patented porous pellets are then used for removing contaminants. All potentially harmful gases and odours emitted during calibration are also scrubbed clean.

Durability

Built into a pelican case for ease of transportation and operation

Inlet

Inlet designed for 0 – 10,000 ml / min dilution

Zero Air Generator

7000 ml / min

Dilution Range

2 to 5000

System

Filter Scrubbers

Power

Built-in Battery, 120 – 240v charger

Filter Scrubbers

 Patented porous pellets