TR8 ODOTRACKER

TR8 Odotracker Handheld Analyzer & Chemical Tracker

A multi-sensor analysis tool that measures the concentrations of two chemicals in ambient air at the same time

Industries

Screen Shot 2022-08-09 at 9.05_edited.png

Detection Threshold

TR8 Odotracker measures chemicals close to the detection threshold at parts per billion (ppb) levels

Screen Shot 2022-08-09 at 9.06_edited.png

Companion Equipment

An Odotracker works great with a personal olfactometer, such as the SM100i. This allows users to determine the concentration of chemical compounds as well as ambient odours

Screen Shot 2022-08-09 at 9.06_edited.png

Automated Data Logging

The TR8 Odotracker provides automated continuous chemical, GPS position, temperature and humidity data logging

Screen Shot 2022-08-09 at 9.06_edited.png

Increased Safety

By providing a constant reading of ambient air, users will receive added protection from over exposure to chemical vapours

scentroid_edited.png

Reporting Standards

Traceable back to international standards: e.g. USEPA (40 CFR part 53) and EU (2008 / 50 / EC)

Screen Shot 2022-08-09 at 9.07_edited.png

Manage Odour Losses

Laboratories can manage odour degradation through sample transportation and storage by analyzing values live and in-field instead

Sewage Filtration

The Perfect Companion Equipment

The GD600 Gas Dilution System can be customized in order to integrate with all Scentroid Analyzers, allowing for easy and affordable calibration with this portable gas diluter.

Related Products

Overview of TR8 Odotracker

The TR8 Odotracker Handheld Analyzer is a multi-sensor analysis tool that measures the concentrations of two chemicals in ambient air at the same time. Chemicals to be measured by the device are specified at the time of ordering. As a result, the user may specify the measurement of Hydrogen Sulphide (H2S) at ppb level and Ammonia (NH3) at ppm level. The TR8 Odotracker is an incredibly helpful tool, because it logs the chemical measurements as well as temperature and humidity of the sample, and GPS location, and automatically transfers all data to the user’s supplied smart Android device via Bluetooth.

A TR8 Odotracker Handheld Analyzer Includes a sampling pump, two chemical sensors that are specified at the time of ordering, and Scentroid’s OdoTracker Application that can be loaded to any customer supplied Android phone/tablet. For each sample location, Scentroid instantaneously records:

  • The concentration of two chemical vapours in ppm or ppb depending on sensors ordered

  • Temperature and humidity

  • GPS position of each measurement

  • Continuously for remote monitoring via Bluetooth

Odotracker Applications

Measure ambient H2S, Ammonia, Total VOC, and other chemical concentrations
Determine H2S, Ammonia, VOCs, and other chemicals emissions from various types of sources
Determine emission trends through 24+ hour data logging
Verify sample loss due to transportation 
Validate dispersion models through emission measurements 

TR8 OdoTracker Operation

  1. Connect to OdoTracker via Bluetooth

  2. Connect the sample bag or allow for ambient air to be pulled in

  3. See chemical readings live

  4. Take snapshot readings of H2S, Ammonia, VOC, other chemical composition, GPS position, temperature, and humidity of the sample

  5. Activate recording for continuous data logging

  6. Export data for reporting and post analysis

Complete Odor Assessment

  1. OdoTracker can be used to record chemical vapours, along with the intelligent personal olfactometer SM100i to do odour concentration measurements, providing simultaneous measurements on one Android device.

Increased Safety

Odotracker will provide the user with constant readings of the ambient air providing added protection from over-exposure to chemical vapours such as hydrogen sulphide.

Measuring Odour Losses

Laboratories can utilize the Odotracker to manage odour losses in sample transportation and storage. For example, H2S and NH3 readings after sampling and before olfactometric analysis will allow the laboratory to determine the level of odour losses and determine if the sample is still valid.

Optional Controlling Module

Odotracker can accommodate an optional controller module that has a 10 amp dry contact relay output to signal if the summation of the customer specified combined scaled chemical readings exceeds a customer specified threshold setting. This relay contact can be used to trigger alarms or switch on ventilation fans, chemical scrubbers or other devices when a combined scaled chemical concentration for the two sensors is reached. A hysteresis span is provided for relay triggering and non-triggering.

Sensors

Maximum Sensors: 10 (Click here for full sensor list)
Type of Sensors: PID, NDIR, EC, Laser Particulate Counter

Sampling

Sampling Rate: Adjustable from 1/s to 1/m
Sampling Ports: 1 to 2
Sampling Range: Range depends on active sensors
Initialization Time: 2 minutes
Settling Time: 0.5 seconds
Pressure Range: 80 – 120 kPa
Additional Parameters Measured: Temperature, relative humidity, GPS position 

Power

Battery Life: 24 hours

Communications

Communication: Bluetooth connection with any android device

Temperature

OdoTracker can be used to record chemical vapours, along with the intelligent personal olfactometer SM100i to do odour concentration measurements, providing simultaneous measurements on one Android device.

Calibration

Manual Calibration: Using calibration gas and on-board screen
Automatic Calibration: Optional, using built-in calibration gas

Warranty

Warranty: 24 months full warranty on all parts including sensors
Sensor Replacement: Sensor dependent; first 2 years are covered by warranty

Hardware

Casing: Heavy duty pelican case ensures components are kept safe
Weight: 1.7 lbs