Military Standard for Durability and Mobility
Built into two rugged pelican cases. Designed to be waterproof and shockproof to Military standards MIL C-4150J & DefStand 81-41

Software Reliability
The SC300P uses Siemens industrial PLC with real time operating systems to ensure reliable operation and a seamless integration with EEG and FNIR instruments

Patented Control Algorithm
The SC300P comes with two rugged waterproof Pelican cases weighing less than 20kg each. There are no additional software or hardware additions required

Unprecedented Dilution Range
Dilution range of 8-131,072 (2^3 – 2^17) with variable step size to a max. of 1000 steps in between surpasses any other commercially available mobile olfactometer

International Standards
Adheres to all international olfactometry standards: EN13725:2003, ASTM E679-04, NVN2820, VDI 3881, GB/T14675-93

Deployment simply requires connecting the power cord to a standard 120/240 VAC outlet and connecting the air supply hose
SC300P Scientific Olfactometer Overview
Scentroid SC300P (Scientific Olfactometer) is a specialized multi-sensory olfactometer with EEG and FNIR capabilities for advanced psychological and physiological research and treatment. The SC300-P has been used by researchers and doctors to treat a variety of disorders including post-traumatic stress disorder.
The SC300P (Scientific Olfactometer with EEG Capabilities) is more than just an olfactometer, but a true multi-sensory stimuli instrument. Up to 8 odours can be connected to the instrument and programmed to be administered to the panellist at various concentrations. Images, videos, and audio stimuli can be simultaneously administered by the SC300P (Scientific Olfactometer with EEG Capabilities) via its external monitor to provide complete sensory immersion.
EEG, FNIR, and EPrime Scientific Olfactometer Connectivity
The SC300P (Scientific Olfactometer with EEG Capabilities) seamlessly integrates with EEG and FNIR machines to provide simultaneous stimuli readings from the panellists. Trigger signals will provide a clear reference on which stimuli were being administered. E-Prime connectivity allows the SC300P to act as a master or as part of a large network of instruments in a comprehensive study.
Use the SC300P Scientific Olfactometer for
-
Olfactory sensitivity testing
-
PTSD study and treatment
-
Multi-sensory psychological studies linking scent to brainwaves
-
Diagnostic and treatment of olfactory disorders
-
Product testing and market research
Basics of Operation of SC300P
-
Clean air is supplied by the portable air supply module
-
Up to 8 samples are connected to the same sample ports and prepared for presentation
-
Panellists are fitted with an EEG cap and the system is set to record responses
-
A test mode is selected, and audio and visual data is loaded for the presentation
-
During each presentation, the SC300P will trigger the EEG with the identification of audio, video and olfactory stimuli presented
-
The SC300P will then present olfactory, audio, and video stimuli in accordance with the defined test mode
Admin
Panel Size: 1 – 8 panellists can participate in a single test, as specified by the administrator
Panel Order Setup: Users can either run 1 test at a time and rotate to the next panellist, or conduct the full test sequence then rotate
Testing Modes: Sensitivity analysis, Audio/Olfactory pulse presentation, Psychological video/olfactory analysis, custom audio/olfactory/ image test mode.
Multiple Odourants: 4 – 8 odourant capabilities (must be specified when ordering) allowing for mixing
Re-calibration: Activated through the admin screen
Dilution
-
Dilution Principle: Venturi educator
Control Mechanism: Mass flow controllers on both clean air and sample air intake
Dilution Range: 2^6 to 2^17 optional range extension
Dilution Steps: Variable
Accuracy: 95%
Control
Control: Siemens PLC
Computer Interface: Ethernet Network / USB
Display: Large 32″ full-colour touch-screen Admin and separate industrial 6″ screen for panellists
Olfactory Interface: Your choice of sniffing port or half-face disposable masks
Medical Interface: EEG (RS232), FNIR (RS232) Eprime (RS232 USB + Ethernet optional)
Data Processing: Test Data including end-criteria and statistics processed through PLC
Languages: English, Chinese, French, German, Turkish, and Spanish