top of page
Scientist with Test Tubes
SS600_Hero_2-300x300.png

SS600 ODOR LABORATORY

World's Most Advanced Dynamic Stationary Olfactory Lab

Scentroid’s SS600 Odour Laboratory is the world’s most advanced stationary, dynamic, and fully automated olfactometer. It is capable of odour measurement and analysis to all international olfactometry standards

Screen Shot 2022-08-15 at 1.35_edited.png

Fast and Efficient

With the world’s shortest sample processing time, the SS600 will allow you to complete seven samples per hour with three rounds and five dilution steps each

Screen Shot 2022-08-15 at 1.44_edited.png

Upgrade Available

Ability to upgrade from the SS600 to the SS800 which features 8 total olfactory stations and the built in admin panel

Screen Shot 2022-08-15 at 1.36_edited.png

SS600 is an Investment

Smallest sample consumption of any olfactometer on the market. Typical 3 round analysis requires only one 10L sample. Save on sampling, shipping, cleaning, purging, etc.

Screen Shot 2022-08-12 at 4.25_edited.png

Accuracy

Uses high-accuracy mass flow controllers to monitor and adjust both sample air and the clean diluting air, ensuring an accurate dilution ratio regardless of variations in ambient pressure or temperature

Screen Shot 2022-08-09 at 9.06_edited.png

International Standards

The SS600 adheres to all international standards including: EN13725:2003, ASTM E679-04, NVN2820, VDI 3881, GB/T14675-93, AS 4323.3

Screen Shot 2022-08-09 at 9.07_edited.png

Siemens control hardware and machine interface coupled with specialized Stainless steel valves, mass flow controllers, and regulators ensures unprecedented reliability

Related Products

Admin

Testing Modes: Triangular forced, binary forced, yes/no, direct presentation, hedonic tone, GB boundary, and GB test
Accuracy: Error less than 2% reading
Response Time: 0.2 s
Setting Time: <1s
Sample Delivery (Sniffing) Time: Adjustable
Required Sample Volume: Depends on test conditions selected; an average 6 panellist test consumes 2 litres by using a 10s sniff time at 20 lpm
Calibration: Full feedback design does not require re-calibration
Power Requirements: 110VAC, 60Hz, 10 Amps or 220VAC/50Hz, 10 Amps
Standards: EN13725:2003, ASTM E679-04, NVN2820, VDI 3881, GB/T14675-93, AS 4323.3

Dilution

Dilution Principle: Venturi vacuum pump using no moving parts to create a vacuum and draw out sample air
Control Mechanism of Volumetric Flow: Mass flow controllers on both clean air and sample intake. Uses full feedback to guarantee accurate dynamic dilution
Dilution Range: 2 to 2^16, with an optional 2 to 2^24 available
Dilution Steps: Selectable, unlimited steps between 2 and 2^16

Controls

Control: Siemens PLC, for fully automated processes. Does not require a computer to operate
Computer Interface: Ethernet Network/USB
Display and Interface: Siemens industrial 8″ full-colour touch screen for administrators and six Siemen’s 6″ industrial touch screens for panellists
Display Languages: English, Italian, French, German, Spanish, Chinese

Hardware

Presentation Device: Stainless Steel Sniffing Ports
Tubing Material: Stainless Steel (316L electro-polished)
Wetted Surfaces: Stainless Steel (316L)
Table Material: All stainless steel construction to eliminate contamination
Dimensions and Weight: 130″ x 47.25″ x 330lbs

Data Processing

Data Processing: Test Data including end-criteria and statistics processed formatted for quick and easy excel imports or other post data processing software
Data Transfer: USB mass storage device support for extraction and storage of data on any standard flash disk or USB HDD

Air Flow

Presentation Flow Rate: Variable, 15 litres per minute to 30 litres per minute
Presentation Face Velocity: 0.25 m/s at 20 litres per minute
Air Supply: Oil-free compressor with water separator, micro-mist separator, maintenance-free drier and carbon filter enclosed in sound-absorbing foam

Dimensions and Weight

24″ x 20″ x 8″ x 81 lbs

Sensors

Maximum Sensors: Up to 13, including preessure, temperature, relative humidity, GPS. (Click here for full sensor list)
Type of Sensors: PID, NDIR, EC, laser particulate counter, MOS

Calibration

Standard: Factory calibration to fully documented procedures in accordance with our
ISO 9001 quality management system
Manual Calibration: Using calibration gas and on-board screen
Automatic Calibration: Optional, using built-in calibration gas

Hardware

Cabinet: NEMA 4X
Mounting Hardware: Wall mounting hardware Included 

Scentinal Package Includes

  • Smart board for data processing and storage

  • Monitoring software

  • Temperature and humidity sensors

  • Min of 3 to a maximum of 10 sensors

  • NEMA 4x Cabinet

  • Ozone generator which decontaminates all lines automatically once per day

Sampling

Sampling Rate: Adjustable from 1/s to 1/m
Sampling Ports: 1 to 2

Power

Sampling Rate: Adjustable from 1/s to 1/m
Sampling Ports: 1 to 2

Temperature

Temperature Range: 0 to 35 °C without AC unit installed
Temperature Range with AC unit:  -50 to 50 °C with heating and AC
Sample Conditions Without Pre-Dilution System: -50 to 50 °C and 10 to 90% RH 
Sample Conditions With Pre-Dilution System: -50 to 120 °C and 0 to 100% RH

Communications

Communication: 3G / 4G (default) LAN (default) WiFi (optional)
On Board Data Storage: 64gb SD Card
Cloud Server: Included by default
Local Server: Optional
On-Board Server: Included by default
User Interface: 7″ touch screen on panel door and remote access to SIMS (Sensor Information Management System)
Software: Free access to SIMS for life of product

Warranty

Warranty: 24 months full warranty on all parts including sensors
Sensor Replacement: Sensor dependent; first 2 years are covered by warranty